breina / powertaggateway Goto Github PK
View Code? Open in Web Editor NEWHomeAssistant integration for EcoStruxure gateways; SmartLink, PowerTag Link and Panel Servers.
License: MIT License
HomeAssistant integration for EcoStruxure gateways; SmartLink, PowerTag Link and Panel Servers.
License: MIT License
Describe the bug
The following sensors is not received from my PAS600, they are just shown as unknown in HA:
sensor.jordvarme_total_active_energy_phase_phase_a
sensor.jordvarme_total_active_energy_phase_phase_b
sensor.jordvarme_total_active_energy_phase_phase_c
I can see them on my PAS600:
Active energy A delivered 230Wh
Active energy B delivered 0Wh
Active energy C delivered 631Wh
Versions
Describe the bug
I always get false alarms on my powertags, see attached picture.
These alarms are activated on my PAS600 on all powertags:
I have a PAS600 as panel server with SW ver. "esxp-pas-universal-v1-1.9.0.sedp"
I have 5 powertags:
2 x A9MEM1560
3 x A9MEM1570
Versions
Bonsoir ,
croyez vous possible d4ajouter ce module .
à votre integration.
super integration.
j'utilise tous les jours des produits schneider
chez moi,
1-A9XMZA08
power tag A9MEM1560
power tag A9MEM1522
MERCI
Describe the bug
The humidity for the CL110 Sensor is missing the factor x100. I'm not sure if this is a problem with HomeAssistant.
The displayed humidity in HA is "0,5512 %" an in PanelServer "55.12 %".
Versions
Logs
Hi
I have tested this integration for a while without issue using a PowerTagLink & one powertag (single phase A9MEM1560) connected through a CPL plug. The plug died but I had a panel sever PAS600 that is wifi connected. this is why I did this change.
I removed the PowerTagLink and replaced it by the PAS600 in the integration module.
I have renamed the sensor in the PAS600 to keep the same sensor name than before.
Info : autodiscovery did not work, I had to fill the IP manually.
I am able to receive the data without issue... for few hours. After that, the sensor is not responding and I cannot access to the Home assistant web page. The data of other HA sensor remains captured by HA and sent to Influx but not the PowerTag.
The only solution was to restart HA container.
PAS600 version 001.008.000
HA : 2023.11.3
I have tested the link with PAS600 with Uptime Kuma and there is a full availablility, no disconnection.
Can you help me ? What else do you need from me to find the issue ?
Hi, is the CCT501901 gateway supported? It comes bundled with a A9MEM1570 powertag in Sweden.
Or I need e.g the PAS400 instead?
Thanks in advance!
It stopped working when I upgraded to V0.4.2.
I tried to uninstall it from Integration and HACS.
But when I installed it again, it was ok in HACS, but when adding the integration I get the error:
Konfigurationsflow kunne ikke indlæses: {"message":"Invalid handler specified"}
Hi,
HA not founding A9MEM1590 R200 3P 3P+N. Can You help?
Logs:
2024-04-11 11:19:35.288 WARNING (MainThread) [root] Unknown product type: 17973.
Attached full debug logs
home-assistant_powertag_gateway_2024-04-11T10-50-59.589Z.log
Update: I change in file product type 17969 to 17973, Start working
Originally posted by @Seveensv in #15 (comment)
Hello, I have two Acti9 PowerTag Link HD - Wireless to Modbus TCP/IP Concentrators (A9XMWD100) and some power meters connected to them:
This might be the same or similar problem to issue #15...?
When I try to connect either A9XMWD100, I encounter a problem. The automatic DPWS discovery finds both of them and I can add them to the integration (v0.2.2).
I get to a problem at this stage. One of the meters seems to get connected fine but the other doesn't - no devices or entities (attached screenshot):
You asked for logs in issue #15 to troubleshoot, so I am attaching the logs I get.
Also attaching the full logs.
If you need any additional logs or further information, please do tell. I'll be happy to provide so we can troubleshoot the problem.
Hi there, not sure if you know about it but the PowerTag Link is now obsolete and replaced by Schneider's PanelServer range
ERROR (MainThread) [homeassistant.config_entries] Error occurred loading flow for integration powertag_gateway: cannot import name 'make_byte_string' from 'pymodbus.utilities' (/usr/local/lib/python3.11/site-packages/pymodbus/utilities.py)
Home Assistant 2023.10.1
OS: Ubuntu 22.04
Docker
This happens when using latest stable version from HACS, and also the beta 1.0.5
Hi
Super integration that works really well...
The gateways that are supported are beeing dicontinued thou... so I was wondering if the replacement product will be worked into this integration?
Also, i am in a position where i have access to this line of products.. so if I can help, reach out to me...
Best regards
Leandrial
After updating the Home assistant version to 2023.2.0, I started receiving errors in the logs (Unable to import component: No module named 'pymodbus.client.sync').
The integration is not loaded, and all sensors became NA.
Appreciate your efforts and your commitment to solving this issue.
Home Assistant 2023.2.0
Supervisor 2023.01.1
Operating System 9.5
Frontend 20230201.0 - latest
Thanks
In our setup, we are using several A9MEM1580 devices. It would be great to have them supported. Happy to send you one of the devices to include it into the integration.
Hey, got your integration working for a few months, now suddenly all entitys are gone and when i try to delete the devices and re add them they are connecting but wont creating any devices or entitys any fix for that?
It seems as there are several lines of PowerTag
It would be great if this integration can support the EER31800 (se.com/dk/da/product/EER31800/wiser-energy-ipmodul/) as this is the cheapest way to get the powerTag's integrated. The ModBus controller are quite expensive compared with this one.
I do understand that it may use a different communication API than ModBus so it may not be possible.
My original hope was to get the actual powertag included through ZigBee however this seems very difficult as well.
And adding the modules R9M22 Energisensor Resi PowerTag 1PN, R9M41 Energisensor Resi PowerTag 3PN, R9M42 Energisensor Resi PowerTag 3PN, (and probably more) would also be needed if the EER31800 can be integrate
Is it also possible to use an Acti 9 Smartlink SI D gateway?
I saw in another topic that there was a possibility for a Smartlink SI B.
I certainly cannot add these automatically and manually at the moment.
Hi Breina,
Due to lack of time and skills I would like to send you some devices for development and testing.
Kind regards,
E-prommer
A declarative, efficient, and flexible JavaScript library for building user interfaces.
🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
An Open Source Machine Learning Framework for Everyone
The Web framework for perfectionists with deadlines.
A PHP framework for web artisans
Bring data to life with SVG, Canvas and HTML. 📊📈🎉
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
Some thing interesting about web. New door for the world.
A server is a program made to process requests and deliver data to clients.
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
Some thing interesting about visualization, use data art
Some thing interesting about game, make everyone happy.
We are working to build community through open source technology. NB: members must have two-factor auth.
Open source projects and samples from Microsoft.
Google ❤️ Open Source for everyone.
Alibaba Open Source for everyone
Data-Driven Documents codes.
China tencent open source team.