HRnV-Calc: Software for Heart Rate n-Variability Analysis

HRnV-Calc Introduction

Description

The HRnV-Calc software is a heart rate variability (HRV) analysis software with the novel Heart Rate n-Variability (HRnV) method built in. The software is built upon the core HRV analysis code provided by PhysioNet Cardiovascular Signal Toolbox (PCST). In addition to the fully automated command-line HRV analysis process provided by PCST, HRnV-Calc offers the HRnV metrics to augment insights discovered by HRV as well as intuitive graphical user interfaces (GUIs) for every major step of HRV and HRnV analysis.

The HRnV-Calc software is available freely on GitHub under the GNU GPL (v3 or later) license.

Installation

To begin, please download and install Matlab (2017b or higher) (required Matlab Toolboxes: Signal Processing Toolbox, Statistics and Machine Learning Toolbox, Neural Network Toolbox, and Image Processing Toolbox)

Before using the GUIs and HRnV analysis provided by HRnV-Calc, users need to install PCST for the core signal analysis and HRV toolkits that HRnV-Calc depends on. Users may use the installation script – ‘Install_Dependency.m’ included in HRnV-Calc to automatically download and install PCST.

Alternatively, PCST can be manually downloaded from PhysioNet and added to the directory containing HRnV-Calc code as a subdirectory. Do note that the name of the folder containing PCST should not be changed, as HRnV-Calc will check the existence of the original PCST folder before the software starts.

Citation

If you are using HRnV-Calc, please cite PCST and other related papers:

[1] Vest, A. N., Da Poian, G., Li, Q., Liu, C., Nemati, S., Shah, A. J., & Clifford, G. D. (2018). 
    An open source benchmarked toolbox for cardiovascular waveform and interval analysis. 
    Physiological measurement, 39(10), 105004. https://doi.org/10.1088/1361-6579/aae021

[2] Liu, N., Guo, D., Koh, Z. X., Ho, A., Xie, F., Tagami, T., Sakamoto, J. T., 
    Pek, P. P., Chakraborty, B., Lim, S. H., Tan, J., & Ong, M. (2020).
    Heart rate n-variability (HRnV) and its application to risk stratification of chest pain patients in the emergency department. 
    BMC cardiovascular disorders, 20(1), 168. https://doi.org/10.1186/s12872-020-01455-8
 

Contact

HRnV/HRV Methods and Metrics

The HRnV Method

To use HRnV-Calc, it is important to know how the HRnV method works. Here we will give a simple explaination of the method. We recommend reading this section with white background (i.e., light mode), as GitHub currently does not support native Latex rendering.

HRnV is a method applied to RRIs (i.e., R to R peak intervals). Therefore, the extraction of RRI from ECG for HRnV is exactly the same as conventional HRV. Once the original RRI is obtained, HRnV will generate new intervals called RRnIm, which is similar to RRI.

There are two parameters to be specified for the HRnV method: the summation parameter n and the stride parameter m. Both n and m can take any positive integer (i.e., n, m >= 1) given that m <= n.

To fully describe the process of RRnIm generation, consider a series of clean RRI (i.e., all outliers and non-sinus beats are removed or processed), of length N. With specified n and m, the RRnIm generated from the input RRI, of length M can be expressed as:

The length of the new series, M, is given by , where represents the floor function. The figure below illustrates a toy example of generating RR3I2 from a RRI series of length 9.

Generation of RRnIm Toy Example

All conventional HRV methods and metrics can then be applied to the new RRnIm intervals (i.e., feed RRnIm into conventional HRV analysis as normal RRI). Such metrics, namely HRnVm metrics, provide additional insights to the conventional HRV.

Metrics Descriptions

A brief description of all HRV/HRnVm metrics provided by HRnV-Calc can be found in the table below.

Metrics Units Description
Tiem Domain
Average RR ms The mean of RR intervals
SDRR ms The standard deviation of RR intervals
Average HR 1/min The mean of heart rate
SDHR 1/min The standard deviation of heart rate
RMSSD ms Square root of the mean squared differences between successive RR intervals
NN50 count Numbers of RR intervals differ more than 50 ms from the previous intervals
pNN50 % Percentage of NN50 intervals within the entire RR intervals
RR Skewness - The skewness of the RR intervals distribution
RR Kurtosis - The kurtosis of the RR intervals distribution
RR Triangular Index - The integral of the RR intervals histogram divided by the height of the histogram
Frequency Domain For more detailed documentations of the frequency domain metrics, check out here.
VLF, LF, and HF Peak frequencies Hz The peak frequencies in the power spectral distribution (PSD) for VLF, LF, and HF bands
VLF, LF, and HF Powers Absolute powers of VLF, LF, and HF bands
VLF, LF, and HF Power Percentages % The percentage for powers of VLF, LF, and HF bands within the overall spectrum
LF and HF Normalized Powers n.u. Normalized powers for LF and HF bands
Total Power The overall power of the PSD
LF/HF - The ratio between the powers of LF and HF bands
Nolinear Domain
Poincare SD1 and SD2 ms The width and length of the eclipse fitted in the Poincare plot
App_Ent - Approximate entropy
Sam_Ent - Sample entropy
DFA α1 and α2 - Short-term and long-term fluctuations of detrended fluctuation analysis (DFA)

HRnV-Calc Tutorial

HRnV-Calc is primarily operated using its step-by-step GUIs, which include four main interfaces: (1) Data Loader, (2) QRS Detection & Edits viewer, (3) HRnVm Setting Viewer, and (4) HRnVm Results Display. Each of these interfaces will be presented one at a time for every step of HRnV and HRV analysis.

In this tutorial, we use the demo ECG input Demo_NSR16786.txt to illustrate functionalities of HRnV-Calc. The demo input is a 10 min ECG recording (sampling rate: 128Hz) randomly sampled from patient #16786 in the MIT-BIH Normal Sinus Rhythm Database.

Data Loader

The initial GUI of HRnV-Calc is Data Loader, which provides basic settings for users to begin HRV/HRnV analysis. Users may choose to perform analysis on a single file or multiple files as batch processing. It is noteworthy that the current version of HRnV-Calc supports only batch processing on RRI (IBI) inputs, which do not require manual QRS inspection to complete the HRV/HRnV analysis.

Data Loader

Data Type and Formats

Currently, HRnV-Calc accepts five different data types, which include:

  • Raw ECG (*.txt, *.csv)
  • IBI (*.txt, *.csv)
  • Kubios ECG files (*.mat) saved by Kubios HRV
  • Kubios IBI (*.mat)
  • ECG PC -- ECG singal with peak positions (*.csv) saved by HRnV-Calc.

Single/Batch Processing

Single File lets users conduct HRV/HRnV analysis on one single input file at a time. This option supports all data types. Once the data type is configured, users may click on the 'Open File/Folder' button to navigate and locate the input file. Note that HRnV-Calc will only display files in supported formats for the specified data type.

Batch Files allows users to conduct HRV/HRnV analyses on multiple RRI input files simultaneously. To conduct batch processing, all input RRI files have to be in the same format (either *.txt or *.mat) and saved under the same directory. Users may use 'Open File/Folder' button to navigate and locate the input directory, and HRnV-Calc will automatically analyze all supported files in the directory. HRnV-Calc includes three demo RRI input files from the Normal Sinus Rhythm RR Interval Database for users to try batch processing.

Adult/Infant Processing Profile

Since infant ECG and RRI signals have distinct features to the ones from adults, HRnV-Calc has two processing profiles for users to choose from for downstream analysis. For more details about the profiles, please refer to the PCST paper.

Sampling Rate

For ECG inputs, users need to specify the sampling rate of the signal. There are two predetermined sampling rates to choose: 125Hz or 250Hz. If the signal is sampled using other rates, users may choose the 'Others' option and type in the sampling rate.

For RRI inputs, this section will not be avaible, as the sampling rate does not affect the analysis on RRI. HRnV-Calc will assign one of the default rates to the input.

Record ID Extraction

By default, HRnV-Calc will use the full file name (e.g., Demo_NSR16786.txt) of the input as record ID to store and display analysis results. Users may customize the ID extraction by specifying the prefix and postfix of the input file. For example, as shown in the figure above and all subsequent figures, record ID 'NSR16786' can be extracted from the file name by specifying the prefix to be 'Demo_' and postfix to be '.txt'.

Cofirmation Window

Once the input files and all settings in the Data Loader are properly configured, users may click on 'Next' to proceed to the next step. A confirmation window will be displayed to let users double check on the settings made in the Data Loader. If it is necessary to change any setting, clicking 'Back' will bring up the Data Loader agian. The 'Next' button will bring up the QRS Detection and Edits (QDE) Viewer for ECG inputs or HRnVm Setting Viewer for RRI inputs.

Setting Confirmation

QRS Detection and Edits (QDE) Viewer

The QDE viewer is designed to configure and inspect QRS detection on ECG signals. All settings and tools for QRS detection and inspection can be found in the setting section at the top.

QDE Viewer

Segmentation of ECG

The ‘Signal Type’ section allows users to choose whether the full ECG or a segment of it should be analyzed.

If the 'Segment' option is selected, the 'Display settings & ECG Segment Selection' section will be availabe to users to navigate and select the desired segment.

There are three choices of segment length can be selected in the segmentation subsection: 5 min, 10 min, and 15 min. Users may change ‘Display Duration’ and ‘Display overlay’ to better navigate and locate the desired part of the ECG signal for segmentation.

As shown in the figure below, to select the starting point of the segment, click the ‘Select start point’ button, and then choose the starting point by clicking on the ECG plot displayed in the middle of the QDE viewer. Single clicks will be plotted on the ECG plot as crossing marks for reference. To avoid unintended inputs, such clicks are not stored as the actual starting points. Users may finalize the choice of the starting point by double clicking on the desired point in the ECG plot. Alternatively, right clicking will also finalize the starting point as the last single click position. It is worth noting that only the horizontal position (i.e., the X-axis coordinate) of the click will be used to locate the starting point of the segment. Once the starting point is finalized, the end point of the segment with specified length will be automatically displayed on the ECG plot as a green dot. Users may finalize the choice of the end point by clicking the ‘Confirm End Point’ button and thus confirm the segmentation of the ECG signal.

Segmentation of ECG

Noise Removal and Local Checkup

Baseline drifts in the ECG signal can be removed by checking the 'Baseline Drfit Removal' option.

Although the jqrs algorithm used in HRnV-Calc is one of the most robust and well-regarded QRS detection methods, it may sometimes yield unexpected annotation results, especially when taking ECG inputs with downwards R peaks (i.e., R peak being the local minimum of the signal). Therefore, HRnV-Calc performs an additional check on the jqrs output to modify the annotation to the local maximum within a small region (10 samples before and after the original jqrs peak annotation, regardless of the sampling rate). If the input has downwards R peaks, the ‘Downwards QRS Peak’ option in the QDE viewer enables HRnV-Calc to modify the annotation to the local minimum. If such a modification is deemed unnecessary, users may uncheck the ‘Modify to local supremum’ option skip the additional check.

Peak Detection and Editing

The 'QRS Peak Detection' button lets users perform QRS detection on the selected ECG segment. The peak annotations will be plotted in the 'Denoised ECG Plot' as red dots.

Manual correction of R peaks can be done in the ‘Denoised ECG Plot’. users may first remove the incorrect R peaks by clicking on the ‘Remove Peak’ button and then double click on the marked peak annotations to remove them. Removal of the R peaks can be stopped by a single right click. Since HRnV-Calc performs checks to verify if there are two R peaks too close to each other, it is advised to always remove the undesired R peaks before adding new ones. All R peaks editing can be reversed by performing the QRS detection again.

To add a new peak annotation to the ECG signal, click on the ‘Add Peak’ button and double click on the point where the new annotation will be added. HRnV-Calc will automatically mark the local maximum (or minimum if ‘Downwards QRS Peak’ is selected) within a small region surrounding the selected point as the new R peak, since manual positioning of the exact R peak can be erroneous. Please note that clicking on the ‘Add Peak’ button will only allow users to add one peak to the signal at a time.

Saving Peak Annotation and Proceed

Mannual edits of the peak annotations can be saved by clicking 'New QRS Manual Edit' button. Once the QRS detection is finalized, users may proceed to HRnVm Setting viewer for downstream analysis by clicking on 'HRnVm Calculation'.

HRnVm Setting Viewer

Before using HRnVm analysis, we recommend reading the explaination of the HRnV method.

HRnVm analyses are configured in the HRnVm Setting viewer. In the 'HRnVm ' section, users may choose to perform a single HRnVm analysis by choosing the option ‘Single’ and specifying the desired n and m values. When choosing the option ‘HRnV (m = n)’, HRnV-Calc will perform HRnV (or HRnVn) analysis on the input depending on the specified n. By default, HRnV-Calc will perform the conventional HRV analysis with n = 1 and m = 1.

HRnVm Setting

The option ‘All’ lets users perform all HRnVm analyses with n and m no greater than the specified n. For example, if n is set to be 2, HRnV-Calc will conduct HR1V (i.e., conventional HRV), HR2V1, and HR2V analyses on the input signal altogether. The default value of n for this option is 1, indicating only the conventional HRV analysis to be performed. Note that the results generated using this option will not be shown in the HRnVm Display, even when n is set to be 1. Users may check the stored Excel sheets for detailed results.

The Ectopic Beats section lets users allows users to specify the threshold (default: 20%) for a beat to be considered as an outlier and to select how outliers should be processed (default: remove). It should be noted that the detection and processing of ectopic beats will only be conducted on the original RRI. All RRnIm intervals will be generated from the processed RRI intervals without further processing.

In the Frequency Domain section, user may choose one of the four PSD methods (default: Lomb) provided in PCST. For details of each PSD estimate method, please refer to the PCST paper.

The Use Kubios Preset option lets users modify the settings of some nonlinear methods used in HRnV-Calc according to the published documentations of Kubios HRV. Note that the preset will not yield identiacal results to the ones generated by Kubios HRV, as the exact processing methods used in Kubios HRV are proprietary.

HRnVm Results Display

HRnV-Calc will display results of a single HRnVm analysis (e.g., HR2V1) in the HRnVm Results Display window. Note the display window will not be activated if users choose to perform multiple HRnVm analyses (by choosing option 'All' in HRnVm Setting Viewer) or to conduct batch processing on multiple input files.

HRnVm Results Display

As shown in figure above, the HRnVm Results Display viewer provides a comprehensive overview of the HRnVm analysis. If the conventional HRV (or HR1V) analysis is performed, the ‘IBI Statistics’ section provides an overview of the abnormal beats presented in the original RRI and the percentage of clean beats in the entire input. For HRnVm analyses other than conventional HRV (e.g., HR2V1), the ‘IBI Statistics’ section will only display the number of beats in the corresponding RRnIm intervals, as preprocessing is only performed on the original RRI before converting to RRnIm intervals.

hrnv-calc's People

Contributors

charlienew avatar guodagang avatar nliulab avatar

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.