me again with another one. Do you have an idea, why I see sudden drops in demand (actually to 0 as reported) when my home consumption is actually not really changed?
Here is an example, the chart shows the reported power on the three phases of my shellyem3 (turquoise, orange and yellow lines) and the output to home from the batteries (as its dark and the batteries have plenty of juice thx to the sun today) in blue and also the combined consumption of all three shelly phases (purple line).
![image](https://private-user-images.githubusercontent.com/13994768/313824799-b73a911e-a527-4273-bd81-5168ff497abc.png?jwt=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJpc3MiOiJnaXRodWIuY29tIiwiYXVkIjoicmF3LmdpdGh1YnVzZXJjb250ZW50LmNvbSIsImtleSI6ImtleTUiLCJleHAiOjE3MTk0MjE1OTAsIm5iZiI6MTcxOTQyMTI5MCwicGF0aCI6Ii8xMzk5NDc2OC8zMTM4MjQ3OTktYjczYTkxMWUtYTUyNy00MjczLWJkODEtNTE2OGZmNDk3YWJjLnBuZz9YLUFtei1BbGdvcml0aG09QVdTNC1ITUFDLVNIQTI1NiZYLUFtei1DcmVkZW50aWFsPUFLSUFWQ09EWUxTQTUzUFFLNFpBJTJGMjAyNDA2MjYlMkZ1cy1lYXN0LTElMkZzMyUyRmF3czRfcmVxdWVzdCZYLUFtei1EYXRlPTIwMjQwNjI2VDE3MDEzMFomWC1BbXotRXhwaXJlcz0zMDAmWC1BbXotU2lnbmF0dXJlPTlkY2NiMDgyODgzYzg3N2MwNjJlYzBlY2Q4YTVkN2YzZmVhZmFkMDVkNDFmYjVjYWRkZWUyZDM0MWU5ZmRlYzEmWC1BbXotU2lnbmVkSGVhZGVycz1ob3N0JmFjdG9yX2lkPTAma2V5X2lkPTAmcmVwb19pZD0wIn0.CRqoAOs7Y7sDteNFvmzACeL9zLeqYJRY95AZCfAjmX4)
Here is the corresponding log output from the time. Note the difference in reported output when "it happens".
2024-03-18 19:49:22,559:INFO: DTU triggers limit function: 488.0 : 493.2
2024-03-18 19:49:22,560:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.5V (48.5|48.5), C:-502W, P:False, F:123.4h, E:13.3h, H:479W, L:474W
2024-03-18 19:49:22,563:INFO: INV: AC:468.5W, AC_Prediction: 463.4W, DC:493.2W, DC_prediction: 488.0W (0.0|0.0|249.6|243.6), L:1600.0W [ 0W]
2024-03-18 19:49:22,565:INFO: SMT: T:ShellyEM3 P:13.8W [ 34.9,34.5,6.3,6.3,8.5,8.6,8.4,10.8,13.8 ] Predict: 12.2W
2024-03-18 19:49:22,569:INFO: Direct connected panels can't cover demand 0.0W/475.6W, trying to get rest from hub.
2024-03-18 19:49:22,569:INFO: Checking if Solarflow is willing to contribute 475.6W ...
2024-03-18 19:49:22,569:INFO: Based on time, solarpower ( 0.0W) minimum charge power (200W) and bypass state (False), hub could contribute 475.6W - Decision path: 2.1.
2024-03-18 19:49:22,569:INFO: Not setting solarflow output limit to 474.0W as it is identical to current limit!
2024-03-18 19:49:22,569:INFO: Solarflow is willing to contribute 474.0W!
2024-03-18 19:49:22,569:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:49:22,569:INFO: Direct connected panel limit is 5W.
2024-03-18 19:49:22,569:INFO: Setting inverter output limit to 10W (1 min moving average of 464W x 4)
2024-03-18 19:49:22,570:INFO: Sun: 06:14 - 18:18 Demand: 475.6W, Panel DC: (0.0|0.0), Hub DC: (249.6|243.6), Inverter Limit: 10.0W, Hub Limit: 474.0W
2024-03-18 19:49:37,053:INFO: SMT triggers limit function: -13.8 : 6.1
2024-03-18 19:49:37,053:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.5V (48.5|48.5), C:-501W, P:False, F:123.4h, E:13.3h, H:478W, L:474W
2024-03-18 19:49:37,056:INFO: INV: AC:468.3W, AC_Prediction: 464.4W, DC:492.9W, DC_prediction: 489.4W (0.0|0.0|249.5|243.4), L:1600.0W [ 0W]
2024-03-18 19:49:37,058:INFO: SMT: T:ShellyEM3 P:-86.1W [ 8.4,10.8,13.8,14.0,9.0,9.1,9.1,-86.1 ] Predict: -13.8W
2024-03-18 19:49:37,062:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:49:37,062:INFO: Setting solarflow output limit to 379.0W
2024-03-18 19:49:37,062:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (249.5|243.4), Inverter Limit: 10.0W, Hub Limit: 379.0W
2024-03-18 19:49:41,049:INFO: SMT triggers limit function: -23.9 : -13.8
2024-03-18 19:49:41,049:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.5V (48.5|48.5), C:-502W, P:False, F:123.4h, E:13.3h, H:479W, L:379W
2024-03-18 19:49:41,052:INFO: INV: AC:469.1W, AC_Prediction: 465.7W, DC:493.7W, DC_prediction: 490.9W (0.0|0.0|249.9|243.8), L:1600.0W [ 0W]
2024-03-18 19:49:41,054:INFO: SMT: T:ShellyEM3 P:-83.1W [ 8.4,10.8,13.8,14.0,9.0,9.1,9.1,-86.1,-83.3,-83.1 ] Predict: -23.9W
2024-03-18 19:49:41,057:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:49:41,058:INFO: Setting solarflow output limit to 310.0W
2024-03-18 19:49:41,058:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (249.9|243.8), Inverter Limit: 10.0W, Hub Limit: 310.0W
2024-03-18 19:49:45,564:INFO: DTU triggers limit function: 494.0 : 488.0
2024-03-18 19:49:45,565:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.5V (48.5|48.5), C:-496W, P:False, F:123.4h, E:13.3h, H:473W, L:310W
2024-03-18 19:49:45,568:INFO: INV: AC:443.4W, AC_Prediction: 469.4W, DC:466.7W, DC_prediction: 494.0W (0.0|0.0|236.0|230.7), L:1600.0W [ 0W]
2024-03-18 19:49:45,570:INFO: SMT: T:ShellyEM3 P:1.9W [ 8.4,10.8,13.8,14.0,9.0,9.1,9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9 ] Predict: -19.7W
2024-03-18 19:49:45,573:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:49:45,574:INFO: Setting solarflow output limit to 258.0W
2024-03-18 19:49:45,574:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (236.0|230.7), Inverter Limit: 10.0W, Hub Limit: 258.0W
2024-03-18 19:49:50,561:INFO: DTU triggers limit function: 500.1 : 494.0
2024-03-18 19:49:50,561:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C:-476W, P:False, F:123.4h, E:13.3h, H:454W, L:258W
2024-03-18 19:49:50,565:INFO: INV: AC:402.4W, AC_Prediction: 475.1W, DC:423.4W, DC_prediction: 500.1W (0.0|0.0|214.4|209.0), L:1600.0W [ 0W]
2024-03-18 19:49:50,567:INFO: SMT: T:ShellyEM3 P:86.2W [ 8.4,10.8,13.8,14.0,9.0,9.1,9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2 ] Predict: -24.6W
2024-03-18 19:49:50,570:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:49:50,570:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:49:50,570:INFO: Setting solarflow output limit to 218.0W
2024-03-18 19:49:50,571:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (214.4|209.0), Inverter Limit: 10.0W, Hub Limit: 218.0W
2024-03-18 19:49:53,561:INFO: DTU triggers limit function: 506.0 : 500.1
2024-03-18 19:49:53,561:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C:-459W, P:False, F:123.4h, E:13.3h, H:438W, L:218W
2024-03-18 19:49:53,564:INFO: INV: AC:373.9W, AC_Prediction: 480.7W, DC:393.5W, DC_prediction: 506.0W (0.0|0.0|199.1|194.4), L:1600.0W [ 0W]
2024-03-18 19:49:53,566:INFO: SMT: T:ShellyEM3 P:132.7W [ 8.4,10.8,13.8,14.0,9.0,9.1,9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7 ] Predict: -26.6W
2024-03-18 19:49:53,569:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:49:53,570:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:49:53,570:INFO: Setting solarflow output limit to 187.0W
2024-03-18 19:49:53,570:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (199.1|194.4), Inverter Limit: 10.0W, Hub Limit: 187.0W
2024-03-18 19:49:56,559:INFO: DTU triggers limit function: 511.9 : 506.0
2024-03-18 19:49:56,560:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C:-446W, P:False, F:123.4h, E:13.3h, H:425W, L:187W
2024-03-18 19:49:56,563:INFO: INV: AC:344.5W, AC_Prediction: 486.3W, DC:362.5W, DC_prediction: 511.9W (0.0|0.0|183.6|178.9), L:1600.0W [ 0W]
2024-03-18 19:49:56,565:INFO: SMT: T:ShellyEM3 P:157.7W [ 14.0,9.0,9.1,9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7 ] Predict: -30.2W
2024-03-18 19:49:56,568:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:49:56,568:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:49:56,569:INFO: Setting solarflow output limit to 146.0W
2024-03-18 19:49:56,569:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (183.6|178.9), Inverter Limit: 10.0W, Hub Limit: 146.0W
2024-03-18 19:50:01,559:INFO: DTU triggers limit function: 519.0 : 511.9
2024-03-18 19:50:01,559:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C:-406W, P:False, F:123.4h, E:13.3h, H:387W, L:146W
2024-03-18 19:50:01,564:INFO: INV: AC:282.4W, AC_Prediction: 493.2W, DC:297.2W, DC_prediction: 519.0W (0.0|0.0|150.4|146.8), L:1600.0W [ 0W]
2024-03-18 19:50:01,567:INFO: SMT: T:ShellyEM3 P:204.0W [ 14.0,9.0,9.1,9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0 ] Predict: -23.7W
2024-03-18 19:50:01,572:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:01,572:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:01,572:INFO: Setting solarflow output limit to 126.0W
2024-03-18 19:50:01,573:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (150.4|146.8), Inverter Limit: 10.0W, Hub Limit: 126.0W
2024-03-18 19:50:04,561:INFO: DTU triggers limit function: 524.3 : 519.0
2024-03-18 19:50:04,561:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C:-376W, P:False, F:123.4h, E:13.3h, H:359W, L:126W
2024-03-18 19:50:04,564:INFO: INV: AC:267.9W, AC_Prediction: 498.1W, DC:282.0W, DC_prediction: 524.3W (0.0|0.0|142.6|139.4), L:1600.0W [ 0W]
2024-03-18 19:50:04,566:INFO: SMT: T:ShellyEM3 P:218.1W [ 14.0,9.0,9.1,9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1 ] Predict: -22.4W
2024-03-18 19:50:04,570:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:04,570:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:04,570:INFO: Setting solarflow output limit to 110.0W
2024-03-18 19:50:04,570:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (142.6|139.4), Inverter Limit: 10.0W, Hub Limit: 110.0W
2024-03-18 19:50:15,454:INFO: Triggering telemetry update: iot/73bkTV/vSU06042/properties/read
2024-03-18 19:50:17,561:INFO: DTU triggers limit function: 518.7 : 524.3
2024-03-18 19:50:17,561:INFO: HUB: S:0.0W [ 0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C:-269W, P:False, F:123.4h, E:13.3h, H:257W, L:110W
2024-03-18 19:50:17,565:INFO: INV: AC:171.1W, AC_Prediction: 496.4W, DC:180.0W, DC_prediction: 518.7W (0.0|0.0|91.0|89.0), L:1600.0W [ 0W]
2024-03-18 19:50:17,567:INFO: SMT: T:ShellyEM3 P:324.2W [ 14.0,9.0,9.1,9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2 ] Predict: -16.8W
2024-03-18 19:50:17,570:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:17,570:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:17,570:INFO: Setting solarflow output limit to 97.0W
2024-03-18 19:50:17,571:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (91.0|89.0), Inverter Limit: 10.0W, Hub Limit: 97.0W
2024-03-18 19:50:25,037:INFO: SMT triggers limit function: -5.8 : -23.9
2024-03-18 19:50:25,038:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C:-195W, P:False, F:123.5h, E:13.4h, H:186W, L: 97W
2024-03-18 19:50:25,041:INFO: INV: AC:107.9W, AC_Prediction: 496.9W, DC:113.5W, DC_prediction: 520.1W (0.0|0.0|57.3|56.2), L:1600.0W [ 0W]
2024-03-18 19:50:25,043:INFO: SMT: T:ShellyEM3 P:389.9W [ 9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9 ] Predict: -5.8W
2024-03-18 19:50:25,046:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:25,046:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:25,046:INFO: Setting solarflow output limit to 73.0W
2024-03-18 19:50:25,047:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (57.3|56.2), Inverter Limit: 10.0W, Hub Limit: 73.0W
2024-03-18 19:50:33,561:INFO: DTU triggers limit function: 510.7 : 518.7
2024-03-18 19:50:33,561:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -98W, P:False, F:123.5h, E:13.4h, H: 94W, L: 73W
2024-03-18 19:50:33,564:INFO: INV: AC:4.7W, AC_Prediction: 483.6W, DC:4.9W, DC_prediction: 510.7W (0.0|0.0|2.3|2.6), L:1600.0W [ 0W]
2024-03-18 19:50:33,566:INFO: SMT: T:ShellyEM3 P:483.4W [ 9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4 ] Predict: -6.2W
2024-03-18 19:50:33,569:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:33,570:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:33,570:INFO: Setting solarflow output limit to 65.0W
2024-03-18 19:50:33,570:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (2.3|2.6), Inverter Limit: 10.0W, Hub Limit: 65.0W
2024-03-18 19:50:34,560:INFO: DTU triggers limit function: 499.1 : 510.7
2024-03-18 19:50:34,560:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -88W, P:False, F:123.5h, E:13.4h, H: 84W, L: 73W
2024-03-18 19:50:34,564:INFO: INV: AC:4.8W, AC_Prediction: 472.5W, DC:5.0W, DC_prediction: 499.1W (0.0|0.0|2.4|2.6), L:1600.0W [ 0W]
2024-03-18 19:50:34,567:INFO: SMT: T:ShellyEM3 P:483.4W [ 9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4 ] Predict: -6.2W
2024-03-18 19:50:34,571:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:34,571:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:34,571:INFO: Setting solarflow output limit to 58.0W
2024-03-18 19:50:34,572:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (2.4|2.6), Inverter Limit: 10.0W, Hub Limit: 58.0W
2024-03-18 19:50:36,560:INFO: DTU triggers limit function: 492.2 : 499.1
2024-03-18 19:50:36,560:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -68W, P:False, F:123.5h, E:13.4h, H: 65W, L: 58W
2024-03-18 19:50:36,564:INFO: INV: AC:4.8W, AC_Prediction: 465.9W, DC:5.0W, DC_prediction: 492.2W (0.0|0.0|2.4|2.6), L:1600.0W [ 0W]
2024-03-18 19:50:36,566:INFO: SMT: T:ShellyEM3 P:483.4W [ 9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4 ] Predict: -6.2W
2024-03-18 19:50:36,569:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:36,569:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:36,570:INFO: Setting solarflow output limit to 52.0W
2024-03-18 19:50:36,570:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (2.4|2.6), Inverter Limit: 10.0W, Hub Limit: 52.0W
2024-03-18 19:50:37,559:INFO: DTU triggers limit function: 484.2 : 492.2
2024-03-18 19:50:37,559:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -60W, P:False, F:123.5h, E:13.4h, H: 58W, L: 52W
2024-03-18 19:50:37,563:INFO: INV: AC:4.8W, AC_Prediction: 458.3W, DC:5.0W, DC_prediction: 484.2W (0.0|0.0|2.4|2.6), L:1600.0W [ 0W]
2024-03-18 19:50:37,565:INFO: SMT: T:ShellyEM3 P:483.4W [ 9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4 ] Predict: -6.2W
2024-03-18 19:50:37,569:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:37,569:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:37,569:INFO: Setting solarflow output limit to 37.0W
2024-03-18 19:50:37,570:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (2.4|2.6), Inverter Limit: 10.0W, Hub Limit: 37.0W
2024-03-18 19:50:38,560:INFO: DTU triggers limit function: 475.3 : 484.2
2024-03-18 19:50:38,560:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -53W, P:False, F:123.5h, E:13.4h, H: 51W, L: 37W
2024-03-18 19:50:38,564:INFO: INV: AC:4.8W, AC_Prediction: 449.9W, DC:5.0W, DC_prediction: 475.3W (0.0|0.0|2.4|2.6), L:1600.0W [ 0W]
2024-03-18 19:50:38,566:INFO: SMT: T:ShellyEM3 P:483.4W [ 9.1,-86.1,-83.3,-83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4 ] Predict: -6.2W
2024-03-18 19:50:38,570:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:38,570:INFO: Setting inverter output limit to 10W (1 min moving average of 10W x 4)
2024-03-18 19:50:38,570:INFO: Setting solarflow output limit to 34.0W
2024-03-18 19:50:38,570:INFO: Sun: 06:14 - 18:18 Demand: 0.0W, Panel DC: (0.0|0.0), Hub DC: (2.4|2.6), Inverter Limit: 10.0W, Hub Limit: 34.0W
2024-03-18 19:50:39,036:INFO: SMT triggers limit function: 16.4 : -5.8
2024-03-18 19:50:39,037:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -53W, P:False, F:123.5h, E:13.4h, H: 51W, L: 37W
2024-03-18 19:50:39,040:INFO: INV: AC:4.8W, AC_Prediction: 440.7W, DC:5.0W, DC_prediction: 465.5W (0.0|0.0|2.4|2.6), L:1600.0W [ 0W]
2024-03-18 19:50:39,042:INFO: SMT: T:ShellyEM3 P:483.6W [ -83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4,483.6 ] Predict: 16.4W
2024-03-18 19:50:39,045:INFO: Direct connected panels can't cover demand 0.0W/457.1W, trying to get rest from hub.
2024-03-18 19:50:39,045:INFO: Checking if Solarflow is willing to contribute 457.1W ...
2024-03-18 19:50:39,046:INFO: Based on time, solarpower ( 0.0W) minimum charge power (200W) and bypass state (False), hub could contribute 457.1W - Decision path: 2.1.
2024-03-18 19:50:39,046:INFO: Setting solarflow output limit to 72.0W
2024-03-18 19:50:39,046:INFO: Solarflow is willing to contribute 72.0W!
2024-03-18 19:50:39,046:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:39,046:INFO: Direct connected panel limit is 5W.
2024-03-18 19:50:39,046:INFO: Setting inverter output limit to 10W (1 min moving average of 62W x 4)
2024-03-18 19:50:39,046:INFO: Sun: 06:14 - 18:18 Demand: 457.1W, Panel DC: (0.0|0.0), Hub DC: (2.4|2.6), Inverter Limit: 10.0W, Hub Limit: 72.0W
2024-03-18 19:50:39,559:INFO: DTU triggers limit function: 465.5 : 475.3
2024-03-18 19:50:39,560:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -47W, P:False, F:123.5h, E:13.4h, H: 45W, L: 72W
2024-03-18 19:50:39,564:INFO: INV: AC:4.8W, AC_Prediction: 440.7W, DC:5.0W, DC_prediction: 465.5W (0.0|0.0|2.4|2.6), L:1600.0W [ 0W]
2024-03-18 19:50:39,566:INFO: SMT: T:ShellyEM3 P:432.6W [ -83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4,483.6,474.1,432.6 ] Predict: 18.2W
2024-03-18 19:50:39,570:INFO: Direct connected panels can't cover demand 0.0W/458.9W, trying to get rest from hub.
2024-03-18 19:50:39,570:INFO: Checking if Solarflow is willing to contribute 458.9W ...
2024-03-18 19:50:39,570:INFO: Based on time, solarpower ( 0.0W) minimum charge power (200W) and bypass state (False), hub could contribute 458.9W - Decision path: 2.1.
2024-03-18 19:50:39,570:INFO: Setting solarflow output limit to 106.0W
2024-03-18 19:50:39,570:INFO: Solarflow is willing to contribute 106.0W!
2024-03-18 19:50:39,571:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:39,571:INFO: Direct connected panel limit is 5W.
2024-03-18 19:50:39,571:INFO: Setting inverter output limit to 10W (1 min moving average of 96W x 4)
2024-03-18 19:50:39,571:INFO: Sun: 06:14 - 18:18 Demand: 458.9W, Panel DC: (0.0|0.0), Hub DC: (2.4|2.6), Inverter Limit: 10.0W, Hub Limit: 106.0W
2024-03-18 19:50:41,561:INFO: DTU triggers limit function: 454.2 : 465.5
2024-03-18 19:50:41,561:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -39W, P:False, F:123.5h, E:13.4h, H: 38W, L:106W
2024-03-18 19:50:41,568:INFO: INV: AC:12.1W, AC_Prediction: 430.4W, DC:25.8W, DC_prediction: 454.2W (0.0|0.0|12.8|13.0), L:1600.0W [ 0W]
2024-03-18 19:50:41,571:INFO: SMT: T:ShellyEM3 P:405.0W [ -83.1,-107.1,-87.3,-87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4,483.6,474.1,432.6,432.7,419.9,405.0 ] Predict: 23.2W
2024-03-18 19:50:41,575:INFO: Direct connected panels can't cover demand 0.0W/453.6W, trying to get rest from hub.
2024-03-18 19:50:41,575:INFO: Checking if Solarflow is willing to contribute 453.6W ...
2024-03-18 19:50:41,575:INFO: Based on time, solarpower ( 0.0W) minimum charge power (200W) and bypass state (False), hub could contribute 453.6W - Decision path: 2.1.
2024-03-18 19:50:41,576:INFO: Setting solarflow output limit to 134.0W
2024-03-18 19:50:41,576:INFO: Solarflow is willing to contribute 134.0W!
2024-03-18 19:50:41,576:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:41,576:INFO: Direct connected panel limit is 5W.
2024-03-18 19:50:41,576:INFO: Setting inverter output limit to 10W (1 min moving average of 124W x 4)
2024-03-18 19:50:41,576:INFO: Sun: 06:14 - 18:18 Demand: 453.6W, Panel DC: (0.0|0.0), Hub DC: (12.8|13.0), Inverter Limit: 10.0W, Hub Limit: 134.0W
2024-03-18 19:50:42,037:INFO: SMT triggers limit function: 56.0 : 16.4
2024-03-18 19:50:42,037:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -39W, P:False, F:123.5h, E:13.4h, H: 38W, L:106W
2024-03-18 19:50:42,041:INFO: INV: AC:45.7W, AC_Prediction: 418.4W, DC:48.1W, DC_prediction: 441.5W (0.0|0.0|24.2|23.9), L:1600.0W [ 0W]
2024-03-18 19:50:42,043:INFO: SMT: T:ShellyEM3 P:404.8W [ -87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4,483.6,474.1,432.6,432.7,419.9,405.0,404.8 ] Predict: 56.0W
2024-03-18 19:50:42,047:INFO: Direct connected panels can't cover demand 0.0W/474.4W, trying to get rest from hub.
2024-03-18 19:50:42,047:INFO: Checking if Solarflow is willing to contribute 474.4W ...
2024-03-18 19:50:42,047:INFO: Based on time, solarpower ( 0.0W) minimum charge power (200W) and bypass state (False), hub could contribute 474.4W - Decision path: 2.1.
2024-03-18 19:50:42,048:INFO: Setting solarflow output limit to 162.0W
2024-03-18 19:50:42,048:INFO: Solarflow is willing to contribute 162.0W!
2024-03-18 19:50:42,048:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:42,048:INFO: Direct connected panel limit is 5W.
2024-03-18 19:50:42,048:INFO: Setting inverter output limit to 10W (1 min moving average of 152W x 4)
2024-03-18 19:50:42,048:INFO: Sun: 06:14 - 18:18 Demand: 474.4W, Panel DC: (0.0|0.0), Hub DC: (24.2|23.9), Inverter Limit: 10.0W, Hub Limit: 162.0W
2024-03-18 19:50:42,561:INFO: DTU triggers limit function: 441.5 : 454.2
2024-03-18 19:50:42,561:INFO: HUB: S:0.0W [ 0.0,0.0 ], B: 81% (80|83), V:48.6V (48.6|48.6), C: -39W, P:False, F:123.5h, E:13.4h, H: 38W, L:106W
2024-03-18 19:50:42,565:INFO: INV: AC:45.7W, AC_Prediction: 418.4W, DC:48.1W, DC_prediction: 441.5W (0.0|0.0|24.2|23.9), L:1600.0W [ 0W]
2024-03-18 19:50:42,567:INFO: SMT: T:ShellyEM3 P:424.0W [ -87.3,-36.2,1.9,1.4,92.5,102.6,102.5,90.5,97.9,97.9,69.0,86.2,86.4,113.8,132.7,132.5,136.8,148.5,148.7,149.1,157.7,157.6,145.4,154.2,154.1,142.0,171.4,171.3,190.5,204.0,204.0,195.5,218.1,218.0,218.3,227.9,228.1,227.4,247.2,247.0,250.8,283.0,283.1,267.1,274.9,275.0,287.7,308.8,309.0,304.9,324.2,324.1,322.9,345.5,345.5,352.7,368.9,368.9,360.3,389.9,389.9,386.5,432.3,432.3,432.3,432.3,432.3,423.2,460.5,460.8,458.5,453.4,452.9,478.6,483.4,483.6,474.1,432.6,432.7,419.9,405.0,404.8,418.1,424.0 ] Predict: 59.2W
2024-03-18 19:50:42,570:INFO: Direct connected panels can't cover demand 0.0W/477.6W, trying to get rest from hub.
2024-03-18 19:50:42,570:INFO: Checking if Solarflow is willing to contribute 477.6W ...
2024-03-18 19:50:42,571:INFO: Based on time, solarpower ( 0.0W) minimum charge power (200W) and bypass state (False), hub could contribute 477.6W - Decision path: 2.1.
2024-03-18 19:50:42,571:INFO: Setting solarflow output limit to 186.0W
2024-03-18 19:50:42,571:INFO: Solarflow is willing to contribute 186.0W!
2024-03-18 19:50:42,571:INFO: Adjusting inverter limit from 0.0W to 5.0W
2024-03-18 19:50:42,571:INFO: Direct connected panel limit is 5W.
2024-03-18 19:50:42,571:INFO: Setting inverter output limit to 10W (1 min moving average of 176W x 4)
2024-03-18 19:50:42,572:INFO: Sun: 06:14 - 18:18 Demand: 477.6W, Panel DC: (0.0|0.0), Hub DC: (24.2|23.9), Inverter Limit: 10.0W, Hub Limit: 186.0W