Energy measurements from the Youless LS120 device
Enter your device ip and optional password in the node settings. Attach a node to the measurements output. Each value type is sent in a separate message with value payload and topics as described below.*not for the /e
In the node config field "page" you can enter the followed options:
/e?f=j/
/// this shows the upload values from the json /e page on the Youless.
/f?f=j/
/// info info per phase /f page in json.
/a?f=j/
/// status info report.
/d?f=j/
/// system info: Mac Firmware version.
The following values are reported with/a?f=j/
:
- cnt: counter in kWh
- pwr: Pwer consumption in Watt
- lvl: moving average level (intensity of reflected light on analog meters)
- dev: deviation of reflection
- det:
- con: connection status
- sts: Time until next status update with online monitoring
- cs0: kWh counter of S0 input
- ps0: Computed power
- raw: raw 10-bit light reflection level (without averaging)
The following values are reported with/e?f=j/
:
- tm: time
- net: net value from n1 + n2 - p1 - p2
- pwr: actual power
- ts0: Time stamp s0
- cs0: s0 meter kWh
- ps0: Power computed s0
- p1: Dilverded kWh Low tarif
- p2: Dilverded kWh High tarif
- n1: Concumed kWh Low tarif
- n2: Concumed kWh High tarif
- gas: Gas meter in m3
- gts:
The following values are reported with/f?f=j/
:
- ver: P1 port version
- tr: Tarrif (1 or 2)
- i1: Ampère Phase 1
- i2: Ampère Phase 2
- i3: Ampère Phase 3
- v1: Voltage Phase 1
- v2: Voltage Phase 2
- v3: Voltage Phase 3
- l1: Watt's Phase 1
- l2: Watt's Phase 2
- l3: Watt's Phase 3
The following values are reported with/d?f=j/
:
- model: Youless model
- fw: Firmware version (available from firmware version 1.5.3)
- mac: mac address from the Youless