Coder Social home page Coder Social logo

hansmi / wp2reg-luxws Goto Github PK

View Code? Open in Web Editor NEW
4.0 2.0 6.0 161 KB

Go code and Prometheus exporter for working with heat pump controllers from Alpha Innotec and other manufacturers.

License: BSD 3-Clause "New" or "Revised" License

Go 100.00%
innotec alpha-innotec nibe golang prometheus-exporter novelan wp2reg luxws luxtronik luxtronik2

wp2reg-luxws's People

Contributors

dependabot[bot] avatar hansmi avatar hlinden avatar ppetr avatar tphakala avatar

Stargazers

 avatar  avatar  avatar  avatar

Watchers

 avatar  avatar

wp2reg-luxws's Issues

Scrape failed: collection via LuxWS protocol failed

In the log as well as in the metrics, I get an error message

Scrape failed: collection via LuxWS protocol failed: item with name "Wärmemenge" not found

Happens with the Linux build as well as on OSX.

Log:

 wp2reg-luxws_0.3.0_darwin_amd64 ./luxws-exporter -controller.address 192.168.1.18:8214 -controller.language de -web.listen-address :8111 -verbose
2022/09/14 22:16:42 Listening on ":8111"
2022/09/14 22:16:42 level=info msg="TLS is disabled." http2=false
2022/09/14 22:17:30 Sending message of type 1: "LOGIN;"
2022/09/14 22:17:30 Received message of type 1: "<?xml version=\"1.0\"?><Navigation id='0x0x2604a0'><item id='0x0x256d50'><name>Informationen</name><item id='0x0x284df0'><name>Temperaturen</name></item><item id='0x0x284e38'><name>Eingänge</name></item><item id='0x0x284e80'><name>Ausgänge</name></item><item id='0x0x284ec8'><name>Ablaufzeiten</name></item><item id='0x0x284da8'><name>Betriebsstunden</name></item><item id='0x0x284d60'><name>Fehlerspeicher</name></item><item id='0x0x284d18'><name>Abschaltungen</name></item><item id='0x0x284cd0'><name>Anlagenstatus</name></item><item id='0x0x284c40'><name>GLT</name></item></item></Navigation>"
2022/09/14 22:17:30 Sending message of type 1: "GET;0x0x256d50"
2022/09/14 22:17:30 Received message of type 1: "<?xml version=\"1.0\"?><Content id='0x0x256d50'><name>Informationen</name><item id='0x0x284df0'><name>Temperaturen</name><item id='0x0x27bd28'><name>Vorlauf</name><value>21.6°C</value></item><item id='0x0x282678'><name>Rücklauf</name><value>21.2°C</value></item><item id='0x0x27e560'><name>Rückl.-Soll</name><value>15.0°C</value></item><item id='0x0x23ab18'><name>Rückl.-Extern</name><value>20.8°C</value></item><item id='0x0x27cb90'><name>Heissgas</name><value>19.8°C</value></item><item id='0x0x280408'><name>Außentemperatur</name><value>18.5°C</value></item><item id='0x0x2802e8'><name>Mitteltemperatur</name><value>20.2°C</value></item><item id='0x0x27d190'><name>Warmwasser-Ist</name><value>45.2°C</value></item><item id='0x0x281d50'><name>Warmwasser-Soll</name><value>49.0°C</value></item></item><item id='0x0x284e38'><name>Eingänge</name><item id='0x0x2744d0'><name>ASD</name><value>Aus</value></item><item id='0x0x266238'><name>EVU</name><value>Ein</value></item><item id='0x0x267870'><name>HD</name><value>Aus</value></item><item id='0x0x266640'><name>MOT</name><value>Ein</value></item><item id='0x0x24e8e8'><name>ND</name><value>Ein</value></item></item><item id='0x0x284e80'><name>Ausgänge</name><item id='0x0x236300'><name>AV-Abtauventil</name><value>Aus</value></item><item id='0x0x241010'><name>BUP</name><value>Aus</value></item><item id='0x0x24f2e8'><name>FUP 1</name><value>Aus</value></item><item id='0x0x26c448'><name>HUP</name><value>Aus</value></item><item id='0x0x265170'><name>Ventilation</name><value>Aus</value></item><item id='0x0x2608d0'><name>Ventil.-BOSUP</name><value>Aus</value></item><item id='0x0x22fb08'><name>Verdichter</name><value>Aus</value></item><item id='0x0x229e80'><name>Verdichter 2</name><value>Aus</value></item><item id='0x0x23c9d0'><name>ZIP</name><value>Aus</value></item><item id='0x0x264658'><name>ZUP</name><value>Aus</value></item><item id='0x0x2592e8'><name>ZWE 1</name><value>Aus</value></item><item id='0x0x235e90'><name>ZWE 2 - SST</name><value>Aus</value></item></item><item id='0x0x284ec8'><name>Ablaufzeiten</name><item id='0x0x27c0f0'><name>WP Seit</name><value>00:00:00</value></item><item id='0x0x26a8b0'><name>ZWE1 seit</name><value>00:00:00</value></item><item id='0x0x251618'><name>ZWE2 seit</name><value>00:00:00</value></item><item id='0x0x23e6f8'><name>Netzeinschaltv.</name><value>00:00:00</value></item><item id='0x0x2809d0'><name>SSP-Zeit</name><value>00:00:00</value></item><item id='0x0x27e3f0'><name>VD-Stand</name><value>18:01:15</value></item><item id='0x0x251d28'><name>HRM-Zeit</name><value>00:00:00</value></item><item id='0x0x23b338'><name>HRW-Zeit</name><value>98:12:56</value></item><item id='0x0x26a650'><name>TDI seit</name><value>00:00:00</value></item><item id='0x0x283f40'><name>Sperre WW</name><value>00:00:00</value></item><item id='0x0x22b818'><name>Abtauen</name><value>01:00:00</value></item><item id='0x0x26af68'><name>Sperre 2.VD HG</name><value>00:00:00</value></item></item><item id='0x0x284da8'><name>Betriebsstunden</name><item id='0x0x25c6c0'><name>Betriebstund. VD1</name><value>12797h</value></item><item id='0x0x26abc0'><name>Impulse Verdichter 1</name><value>14279</value></item><item id='0x0x26b360'><name>Laufzeit Ø VD1</name><value>00:53</value></item><item id='0x0x2434f8'><name>Betriebstund. VD2</name><value>12722h</value></item><item id='0x0x282c98'><name>ImpulseVerdichter 2</name><value>14279</value></item><item id='0x0x267e88'><name>Laufzeit Ø VD2</name><value>00:53</value></item><item id='0x0x232528'><name>Betriebstunden ZWE1</name><value>83h</value></item><item id='0x0x267b28'><name>Betriebstunden ZWE2</name><value>803h</value></item><item id='0x0x2336c0'><name>Betriebstunden WP</name><value>23079h</value></item><item id='0x0x249a98'><name>Betriebstunden Heiz.</name><value>19903h</value></item><item id='0x0x278730'><name>Betriebstunden WW</name><value>3167h</value></item></item><item id='0x0x284d60'><name>Fehlerspeicher</name><item id='0x0x282350'><name>21.10.14 23:22:38</name><value>Hochdruckstörung (716)</value></item><item id='0x0x2813f0'><name>21.10.14 05:50:53</name><value>Hochdruck Abschalt. (715)</value></item><item id='0x0x27e1f8'><name>21.10.14 05:30:46</name><value>Hochdruck Abschalt. (715)</value></item><item id='0x0x2839b8'><name>21.10.14 05:10:50</name><value>Hochdruck Abschalt. (715)</value></item><item id='0x0x2843d8'><name>21.10.14 04:50:44</name><value>Hochdruck Abschalt. (715)</value></item></item><item id='0x0x284d18'><name>Abschaltungen</name><item id='0x0x27e090'><name>14.09.22 04:01:05</name><value>keine Anf.</value></item><item id='0x0x281248'><name>13.09.22 04:07:03</name><value>keine Anf.</value></item><item id='0x0x27c818'><name>12.09.22 04:35:24</name><value>keine Anf.</value></item><item id='0x0x282230'><name>09.09.22 23:30:55</name><value>keine Anf.</value></item><item id='0x0x283ad8'><name>09.09.22 04:05:57</name><value>keine Anf.</value></item></item><item id='0x0x284cd0'><name>Anlagenstatus</name><item id='0x0x255b08'><name>Wärmepumpen Typ</name><value>L2A</value></item><item id='0x0x27cdb0'><name>Softwarestand</name><value>V1.86.2</value></item><item id='0x0x26fc90'><name>Bivalenz Stufe</name><value>1</value></item><item id='0x0x2776e0'><name>Betriebszustand</name><value>----</value></item></item><item id='0x0x284c40'><name>GLT</name><item id='0x0x233708'><name>Art</name><value>Aus</value></item></item></Content>"
2022/09/14 22:17:30 Scrape failed: collection via LuxWS protocol failed: item with name "Wärmemenge" not found

Metrics

# HELP go_build_info Build information about the main Go module.
# TYPE go_build_info gauge
go_build_info{checksum="",path="github.com/hansmi/wp2reg-luxws",version="(devel)"} 1
# HELP go_gc_duration_seconds A summary of the pause duration of garbage collection cycles.
# TYPE go_gc_duration_seconds summary
go_gc_duration_seconds{quantile="0"} 0
go_gc_duration_seconds{quantile="0.25"} 0
go_gc_duration_seconds{quantile="0.5"} 0
go_gc_duration_seconds{quantile="0.75"} 0
go_gc_duration_seconds{quantile="1"} 0
go_gc_duration_seconds_sum 0
go_gc_duration_seconds_count 0
# HELP go_goroutines Number of goroutines that currently exist.
# TYPE go_goroutines gauge
go_goroutines 7
# HELP go_info Information about the Go environment.
# TYPE go_info gauge
go_info{version="go1.19"} 1
# HELP go_memstats_alloc_bytes Number of bytes allocated and still in use.
# TYPE go_memstats_alloc_bytes gauge
go_memstats_alloc_bytes 1.517832e+06
# HELP go_memstats_alloc_bytes_total Total number of bytes allocated, even if freed.
# TYPE go_memstats_alloc_bytes_total counter
go_memstats_alloc_bytes_total 1.517832e+06
# HELP go_memstats_buck_hash_sys_bytes Number of bytes used by the profiling bucket hash table.
# TYPE go_memstats_buck_hash_sys_bytes gauge
go_memstats_buck_hash_sys_bytes 6115
# HELP go_memstats_frees_total Total number of frees.
# TYPE go_memstats_frees_total counter
go_memstats_frees_total 769
# HELP go_memstats_gc_sys_bytes Number of bytes used for garbage collection system metadata.
# TYPE go_memstats_gc_sys_bytes gauge
go_memstats_gc_sys_bytes 7.839712e+06
# HELP go_memstats_heap_alloc_bytes Number of heap bytes allocated and still in use.
# TYPE go_memstats_heap_alloc_bytes gauge
go_memstats_heap_alloc_bytes 1.517832e+06
# HELP go_memstats_heap_idle_bytes Number of heap bytes waiting to be used.
# TYPE go_memstats_heap_idle_bytes gauge
go_memstats_heap_idle_bytes 4.415488e+06
# HELP go_memstats_heap_inuse_bytes Number of heap bytes that are in use.
# TYPE go_memstats_heap_inuse_bytes gauge
go_memstats_heap_inuse_bytes 3.514368e+06
# HELP go_memstats_heap_objects Number of allocated objects.
# TYPE go_memstats_heap_objects gauge
go_memstats_heap_objects 5297
# HELP go_memstats_heap_released_bytes Number of heap bytes released to OS.
# TYPE go_memstats_heap_released_bytes gauge
go_memstats_heap_released_bytes 4.415488e+06
# HELP go_memstats_heap_sys_bytes Number of heap bytes obtained from system.
# TYPE go_memstats_heap_sys_bytes gauge
go_memstats_heap_sys_bytes 7.929856e+06
# HELP go_memstats_last_gc_time_seconds Number of seconds since 1970 of last garbage collection.
# TYPE go_memstats_last_gc_time_seconds gauge
go_memstats_last_gc_time_seconds 0
# HELP go_memstats_lookups_total Total number of pointer lookups.
# TYPE go_memstats_lookups_total counter
go_memstats_lookups_total 0
# HELP go_memstats_mallocs_total Total number of mallocs.
# TYPE go_memstats_mallocs_total counter
go_memstats_mallocs_total 6066
# HELP go_memstats_mcache_inuse_bytes Number of bytes in use by mcache structures.
# TYPE go_memstats_mcache_inuse_bytes gauge
go_memstats_mcache_inuse_bytes 9600
# HELP go_memstats_mcache_sys_bytes Number of bytes used for mcache structures obtained from system.
# TYPE go_memstats_mcache_sys_bytes gauge
go_memstats_mcache_sys_bytes 15600
# HELP go_memstats_mspan_inuse_bytes Number of bytes in use by mspan structures.
# TYPE go_memstats_mspan_inuse_bytes gauge
go_memstats_mspan_inuse_bytes 54808
# HELP go_memstats_mspan_sys_bytes Number of bytes used for mspan structures obtained from system.
# TYPE go_memstats_mspan_sys_bytes gauge
go_memstats_mspan_sys_bytes 65280
# HELP go_memstats_next_gc_bytes Number of heap bytes when next garbage collection will take place.
# TYPE go_memstats_next_gc_bytes gauge
go_memstats_next_gc_bytes 4.194304e+06
# HELP go_memstats_other_sys_bytes Number of bytes used for other system allocations.
# TYPE go_memstats_other_sys_bytes gauge
go_memstats_other_sys_bytes 837725
# HELP go_memstats_stack_inuse_bytes Number of bytes in use by the stack allocator.
# TYPE go_memstats_stack_inuse_bytes gauge
go_memstats_stack_inuse_bytes 458752
# HELP go_memstats_stack_sys_bytes Number of bytes obtained from system for stack allocator.
# TYPE go_memstats_stack_sys_bytes gauge
go_memstats_stack_sys_bytes 458752
# HELP go_memstats_sys_bytes Number of bytes obtained from system.
# TYPE go_memstats_sys_bytes gauge
go_memstats_sys_bytes 1.715304e+07
# HELP go_threads Number of OS threads created.
# TYPE go_threads gauge
go_threads 7
# HELP luxws_elapsed_duration_seconds Elapsed time
# TYPE luxws_elapsed_duration_seconds gauge
luxws_elapsed_duration_seconds{name="Abtauen"} 3600
luxws_elapsed_duration_seconds{name="HRM-Zeit"} 0
luxws_elapsed_duration_seconds{name="HRW-Zeit"} 354150
luxws_elapsed_duration_seconds{name="Netzeinschaltv."} 0
luxws_elapsed_duration_seconds{name="SSP-Zeit"} 0
luxws_elapsed_duration_seconds{name="Sperre 2.VD HG"} 0
luxws_elapsed_duration_seconds{name="Sperre WW"} 0
luxws_elapsed_duration_seconds{name="TDI seit"} 0
luxws_elapsed_duration_seconds{name="VD-Stand"} 65449
luxws_elapsed_duration_seconds{name="WP Seit"} 0
luxws_elapsed_duration_seconds{name="ZWE1 seit"} 0
luxws_elapsed_duration_seconds{name="ZWE2 seit"} 0
# HELP luxws_exporter_build_info A metric with a constant '1' value labeled by version, revision, branch, and goversion from which luxws_exporter was built.
# TYPE luxws_exporter_build_info gauge
luxws_exporter_build_info{branch="",goversion="go1.19",revision="",version=""} 1
# HELP luxws_heat_quantity Heat quantity
# TYPE luxws_heat_quantity gauge
luxws_heat_quantity{unit=""} 0
# HELP luxws_info Controller information
# TYPE luxws_info gauge
luxws_info{hptype="L2A",swversion="V1.86.2"} 1
# HELP luxws_input Input values
# TYPE luxws_input gauge
luxws_input{name="ASD",unit="bool"} 0
luxws_input{name="EVU",unit="bool"} 1
luxws_input{name="HD",unit="bool"} 0
luxws_input{name="MOT",unit="bool"} 1
luxws_input{name="ND",unit="bool"} 1
# HELP luxws_operating_duration_seconds Operating time
# TYPE luxws_operating_duration_seconds gauge
luxws_operating_duration_seconds{name="Betriebstund. VD1"} 4.60692e+07
luxws_operating_duration_seconds{name="Betriebstund. VD2"} 4.57992e+07
luxws_operating_duration_seconds{name="Betriebstunden Heiz."} 7.16508e+07
luxws_operating_duration_seconds{name="Betriebstunden WP"} 8.30844e+07
luxws_operating_duration_seconds{name="Betriebstunden WW"} 1.14012e+07
luxws_operating_duration_seconds{name="Betriebstunden ZWE1"} 298800
luxws_operating_duration_seconds{name="Betriebstunden ZWE2"} 2.8908e+06
luxws_operating_duration_seconds{name="ImpulseVerdichter 2"} 5.14044e+07
luxws_operating_duration_seconds{name="Laufzeit Ø VD1"} 3180
luxws_operating_duration_seconds{name="Laufzeit Ø VD2"} 3180
# HELP luxws_operational_mode Operational mode
# TYPE luxws_operational_mode gauge
luxws_operational_mode{mode="----"} 1
# HELP luxws_output Output values
# TYPE luxws_output gauge
luxws_output{name="AV-Abtauventil",unit="bool"} 0
luxws_output{name="BUP",unit="bool"} 0
luxws_output{name="FUP 1",unit="bool"} 0
luxws_output{name="HUP",unit="bool"} 0
luxws_output{name="Ventil.-BOSUP",unit="bool"} 0
luxws_output{name="Ventilation",unit="bool"} 0
luxws_output{name="Verdichter",unit="bool"} 0
luxws_output{name="Verdichter 2",unit="bool"} 0
luxws_output{name="ZIP",unit="bool"} 0
luxws_output{name="ZUP",unit="bool"} 0
luxws_output{name="ZWE 1",unit="bool"} 0
luxws_output{name="ZWE 2 - SST",unit="bool"} 0
# HELP luxws_temperature Sensor temperature
# TYPE luxws_temperature gauge
luxws_temperature{name="Außentemperatur",unit="degC"} 17.7
luxws_temperature{name="Heissgas",unit="degC"} 19.8
luxws_temperature{name="Mitteltemperatur",unit="degC"} 20.2
luxws_temperature{name="Rückl.-Extern",unit="degC"} 20.8
luxws_temperature{name="Rückl.-Soll",unit="degC"} 15
luxws_temperature{name="Rücklauf",unit="degC"} 21.1
luxws_temperature{name="Vorlauf",unit="degC"} 21.5
luxws_temperature{name="Warmwasser-Ist",unit="degC"} 45.2
luxws_temperature{name="Warmwasser-Soll",unit="degC"} 49
# HELP luxws_up Whether scrape was successful
# TYPE luxws_up gauge
luxws_up{status="collection via LuxWS protocol failed: item with name \"Wärmemenge\" not found"} 0

Release 0.2.1

Could you make another release with the latest changes?

Sidenote:
I tried to build it myself, but could not run the executable built as shown below, probably line-feed problems in the code?
Error I got when running "docker run -it wp2reg:latest"

standard_init_linux.go:211: exec user process caused "no such file or directory"

Dockerfile I used:

#################
## Build
#################
FROM golang:1.16-buster AS build

RUN git clone https://github.com/hansmi/wp2reg-luxws.git
WORKDIR wp2reg-luxws/luxws-exporter
ENV GOOS=linux
ENV GOARCH=amd64
RUN go build -o /bin/luxws-exporter

#################
## Runtime
#################

FROM alpine:latest
RUN apk add bash 
RUN apk --update add busybox-extras
RUN mkdir -p /run

COPY --from=build /bin/luxws-exporter /run/

EXPOSE 8111
CMD ["/run/luxws-exporter", "-verbose", "-controller.address", "192.168.1.18:8214", "-controller.language", "de", "-web.listen-address", ":8111"]

Error memory list fails to parse when there are not enough entries

There are only 2 entries in the error memory list. The remaining 3 rows are filled up with '----' as key and value. The exporter fails parsing them because it cannot convert '----' to a date.

image

Output from the exporter:

2022/03/27 21:32:44 Scrape failed: collection via LuxWS protocol failed: parsing time "----" as "02.01.06 15:04:05": cannot parse "----" as "02"
2022/03/27 21:32:48 Scrape failed: collection via LuxWS protocol failed: parsing time "----" as "02.01.06 15:04:05": cannot parse "----" as "02"
2022/03/27 21:32:50 Scrape failed: collection via LuxWS protocol failed: parsing time "----" as "02.01.06 15:04:05": cannot parse "----" as "02"

Flow throughput of heat pump is parsed incorrect when there is no heat demand

When there is no demand for heat, the circulation pump stops pumping water around. The heat pump UI shows '--- l/h' as flow rate (litre/hour). The exporter shows the following output:

Scrape failed: collection via LuxWS protocol failed: unrecognized measurement format "--- l/h"

image
The headers show "temperatures", "inputs", "outputs". "Debiet" means "flow rate".

using SmartGrid features creates parsing error

I've started using the SmartGrid feature on my Novelan LAD7 today. wp2reg-luxws 0.4.0 does fail to parse the state XML from the heatpump since then.

A verbose log is attached here: journal.txt

I suspect this value in this element to be the culprit: newelement2

values can range from 1 to 4 with the following meanings:

1 - EVU lockdown active, compressor won't start
2 - operation at lowered temperatures (to save electric energy)
3 - normal operation
4 - operation at raised temperatures (to store excessive electric energy as heat energy)

If you could add this key to the exporter, that would be nice. Thank you :)

Add support for "used energy"

Luxtronik V3.88 apparently adds "used energy" (de. "Eingesetzte Energie"), which could be useful to compute COP / SEER (de. JAZ).

The layout mimics that of Output Energy ("Wärmemenge") and lists values for heating, water, and total.

The values are also referenced in newer manuals, e.g. here (de):

"Eingesetzte Energie: ELektrische Energie in kW/h, die der Anlage zugeführt wurde" (sic!)

How the heatpump web frontend renders it:
image

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.