issuluca avatar issuluca commented on June 4, 2024

Hi,
I also have the same problem, until version 2.0xx everything worked correctly, now it doesn't work anymore, and I can't even delete the device.
Thanks
Luca

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

Could you please add the model FIMER UNO-DM-5.0-TL-PLUS to the database, which is identified with the code -3P25-?

Ciao Domenico. As explained on the forum, I need the info from the log, you should find this kind of "error" with the data needed to update the list, I need the OptModel and OptModelInt values from that line:

(opt_comm_model) Model unknown, report to @alexdelprete on the forum the following data: Manuf.: ABB - Model: -3P31- - Options: 0x10ED/0xFF69/ - OptModel: 0x10ED/0xFF69/ - OptModelInt: 16

Also, I'm facing an issue due to an error following the installation of the latest version (2.2.1) due to pymodbus not working. Could you please help me in solving this, please?

You need to provide me more info. "not working" doesn't help me understand what your problem is. What error do you have when installing? When do you have the error, when installing or configuring it? Or after the configuration? Try to be detailed.

Anyway, try latest version I just released: v2.3.0 and let me know. Also, make sure you're not using the modbus native integration in config.yml, other users have had problems because they forgot to disable modbus integration when they switched to this component.

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

I also have the same problem, until version 2.0xx everything worked correctly, now it doesn't work anymore, and I can't even delete the device.

"Doesn't work" will not allow me to help understanding what's your problem. You have to be more specific, provide log errors etc.

Also, your problem might not be the same Domenico has. Open a separate issue if needed.

from ha-abb-powerone-pvi-sunspec.

usrpend avatar usrpend commented on June 4, 2024

FIMER UNO-DM-5.0-TL-PLUS

manufacturer: ABB
Model: -3P25-
Options: 0x0FED/0xFF69/
Slave ID: 1
Base Address: 40000
Inverter Type: 101
Inverter Type: Single Phase

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

Thanks. Could you paste here the log lines from HA please? They contain some needed values.

from ha-abb-powerone-pvi-sunspec.

usrpend avatar usrpend commented on June 4, 2024

2023-01-22 16:13:18.632 ERROR (MainThread) [pymodbus.client.sync] Connection to (192.168.1.102, 502) failed: timed out
2023-01-22 16:13:18.654 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Manufacturer: ABB
2023-01-22 16:13:18.655 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Model: -3P25-
2023-01-22 16:13:18.657 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Options: 0x0FED/0xFF69/
2023-01-22 16:13:18.671 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Slave ID: 1
2023-01-22 16:13:18.673 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Base Address: 40000
2023-01-22 16:13:18.674 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Inverter Type: 101
2023-01-22 16:13:18.676 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec.sensor] Model: -3P25-
2023-01-22 16:13:18.678 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec.sensor] manufacturer: ABB
2023-01-22 16:13:18.679 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec.sensor] SW Version: 2201A
2023-01-22 16:13:18.681 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec.sensor] Inverter Type: Single Phase
2023-01-22 16:13:18.703 ERROR (MainThread) [homeassistant.components.sensor] Error while setting up abb_powerone_pvi_sunspec platform for sensor
Traceback (most recent call last):
File "/usr/src/homeassistant/homeassistant/helpers/entity_platform.py", line 281, in _async_setup_platform
await asyncio.shield(task)
File "/config/custom_components/abb_powerone_pvi_sunspec/sensor.py", line 20, in async_setup_entry
hub.read_modbus_data_inverter()
File "/config/custom_components/abb_powerone_pvi_sunspec/init.py", line 243, in read_modbus_data_inverter
inverter_data = self.read_holding_registers(unit=self._slave_id, address=(self._base_addr + 4), count=64)
File "/config/custom_components/abb_powerone_pvi_sunspec/init.py", line 181, in read_holding_registers
return self._client.read_holding_registers(address, count, **kwargs)
File "/usr/local/lib/python3.10/site-packages/pymodbus/client/common.py", line 114, in read_holding_registers
return self.execute(request)
File "/usr/local/lib/python3.10/site-packages/pymodbus/client/sync.py", line 108, in execute
pymodbus.exceptions.ConnectionException: Modbus Error: [Connection] Failed to connect[ModbusTcpClient(192.168.1.102:502)]
2023-01-22 16:13:38.734 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Manufacturer: ABB
2023-01-22 16:13:38.736 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Model: -3P25-
2023-01-22 16:13:38.737 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Options: 0x0FED/0xFF69/
2023-01-22 16:13:38.750 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Slave ID: 1
2023-01-22 16:13:38.752 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Base Address: 40000
2023-01-22 16:13:38.754 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Inverter Type: 101
2023-01-22 16:13:58.723 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Manufacturer: ABB
2023-01-22 16:13:58.724 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Model: -3P25-
2023-01-22 16:13:58.725 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Options: 0x0FED/0xFF69/
2023-01-22 16:13:58.743 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Slave ID: 1
2023-01-22 16:13:58.744 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Base Address: 40000
2023-01-22 16:13:58.745 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Inverter Type: 101
2023-01-22 16:14:21.716 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Reading data failed! Please check Slave ID: 1
2023-01-22 16:14:21.717 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Reading data failed! Please check Reg. Base Address: 40000
2023-01-22 16:14:25.514 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Manufacturer: ABB
2023-01-22 16:14:25.515 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Model: -3P25-
2023-01-22 16:14:25.516 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Options: 0x0FED/0xFF69/
2023-01-22 16:14:25.544 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Slave ID: 1
2023-01-22 16:14:25.545 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Base Address: 40000
2023-01-22 16:14:25.546 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Inverter Type: 101
2023-01-22 16:14:25.547 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec.sensor] Model: -3P25-
2023-01-22 16:14:25.548 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec.sensor] manufacturer: ABB
2023-01-22 16:14:25.549 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec.sensor] SW Version: 2201A
2023-01-22 16:14:25.549 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec.sensor] Inverter Type: Single Phase
2023-01-22 16:14:41.787 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Manufacturer: ABB
2023-01-22 16:14:41.788 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Model: -3P25-
2023-01-22 16:14:41.790 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Options: 0x0FED/0xFF69/
2023-01-22 16:14:44.794 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Slave ID: 1
2023-01-22 16:14:44.795 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Base Address: 40000
2023-01-22 16:14:44.796 ERROR (MainThread) [custom_components.abb_powerone_pvi_sunspec] Reading data failed! Please check Slave ID: 1

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

Do you have in the logs lines that contain text that says to contact me to report the model etc.? Search for "alexdelprete" in the log.

I see from the log that your component doesn't connect, you didn't solve the problem? Is the Slave ID correct? Is the Base Address correct?

from ha-abb-powerone-pvi-sunspec.

usrpend avatar usrpend commented on June 4, 2024

Alex, I searched the logs but I'm not able to find "alexdelprete" in it.
I'm currently running v. 2.0.5-beta.2 which is quite old, but I did not update because of the errors I was receiving with newer versions.
The slave ID 1 seems to be correct, communication is working and also QModMaster is able to retrieve values starting address 40000

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

That log above reports 3 different READ DATA ERRORS. It means it wasn't able to contact the inverter (or the VSN300). How is it working? It happens often?

from ha-abb-powerone-pvi-sunspec.

usrpend avatar usrpend commented on June 4, 2024

No, it was today, due to an update of HACS software. After that, all is working correctly.

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

Did you try latest version? I'm also about to release a newer version that allows to configure the parameters at runtime. Try it and let me know...old versions are not recommended anymore. :)

from ha-abb-powerone-pvi-sunspec.

usrpend avatar usrpend commented on June 4, 2024

Thanks Alex, I will try and let you know in case I need your great assistance

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

No problem. Let me know if something doesn't work.

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

UNO-DM-5.0-TL-PLUS

Added your model to the known list. It'll be included in next release.

from ha-abb-powerone-pvi-sunspec.

usrpend avatar usrpend commented on June 4, 2024

Hello Alex,
I installed the new version after updating HA Core.
HA receives data from my 2 inverters, the model is now recognised but LOG is showing the folowing error regarding modbus:

2023-01-23 11:00:19.614 WARNING (SyncWorker_3) [homeassistant.loader] We found a custom integration hacs which has not been tested by Home Assistant. This component might cause stability problems, be sure to disable it if you experience issues with Home Assistant
2023-01-23 11:00:19.616 WARNING (SyncWorker_3) [homeassistant.loader] We found a custom integration abb_powerone_pvi_sunspec which has not been tested by Home Assistant. This component might cause stability problems, be sure to disable it if you experience issues with Home Assistant
2023-01-23 11:00:41.597 ERROR (MainThread) [homeassistant.setup] Setup failed for modbus: Unable to import component: No module named 'pymodbus.client.sync'

Also, another device which uses modbus does not work, seemingly due to some sort of conflict.

Could you please help me in solving this?
Thanks again for your great support,
Domenico

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

2023-01-23 11:00:19.614 WARNING (SyncWorker_3) [homeassistant.loader] We found a custom integration hacs which has not been tested by Home Assistant. This component might cause stability problems, be sure to disable it if you experience issues with Home Assistant
2023-01-23 11:00:19.616 WARNING (SyncWorker_3) [homeassistant.loader] We found a custom integration abb_powerone_pvi_sunspec which has not been tested by Home Assistant. This component might cause stability problems, be sure to disable it if you experience issues with Home Assistant

These are not an issue, it's a standard msg from HA when you use a custom component that is not an official integration. No worries.

2023-01-23 11:00:41.597 ERROR (MainThread) [homeassistant.setup] Setup failed for modbus: Unable to import component: No module named 'pymodbus.client.sync'

Also, another device which uses modbus does not work, seemingly due to some sort of conflict.

Another user reported this, he was using the component and also modbus: integration, and they conflicted (I don't know why, I used the two together in the past with no issues).

Try disabling the modbus: integration for now, commenting the lines of the other device in the config, and restart HA, so we're sure my component is working. Once you verify it's working, readd the modbus: integration for the other device and restart HA, tell me what happens.

BTW: I didn't release the new version with your model, how can it show up? Let me see the list of the sensors with the model so I can check how it's identified. Thanks.

from ha-abb-powerone-pvi-sunspec.

alexdelprete avatar alexdelprete commented on June 4, 2024

@usrpend I opened a separate issue about the modbus: conflict.

I'll close this one, ok?

from ha-abb-powerone-pvi-sunspec.

Related Issues (20)

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.